Customization: | Available |
---|---|
After-sales Service: | Provide Installation and Commissioning Guidance. |
Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Tailored for the petrochemical industry, this compact power solution is ideal for driving small pump systems. With steam inlet pressure ranging from 1.0 to 5.0 MPa and power output of 10-150 kW, it adapts flexibly to diverse operational needs. Featuring a skid-mounted design, it ensures compact integration, easy installation, and rapid deployment. Compliant with API 611/612, ASME, and GB standards, it guarantees high reliability, low maintenance, and extended service life. Customizable configurations meet complex working conditions, balancing energy efficiency with operational stability-empowering your cost-saving and productivity goals!
Key Benefits
Overall dimension drawing
Cross-sectional drawing
Optimized design
Item | Unit | Data |
Product Code | T400 | |
Rated Speed (Gearbox Reduction) | r/min | 1500 or 3000 |
Number of Turbine Stages | 1 regulation stages | |
Governor Type | PLC Regulation or Woodward TG 13/17 | |
Overspeed Protection Method | Two-out-of-three electrical overspeed protection + mechanical overspeed protection | |
Overspeed Protection Actuation Speed | Rated speed × (1.09 - 1.11) | |
Overspeed Protection Response Time | s | <0.5 |
Vibration Value at Rated Speed | mm | ≤0.03 |
Vibration Value at Critical Speed | mm | ≤0.15 |
Maximum Axial Displacement | mm | ±0.2 |
Weight | t | 0.69 |
Bearing Lubrication Type | Self-lubrication by oil - slinging ring | |
Bearing Alarm Temperature | ºC | 85 |
Turbine Dimensions (Length × Width × Height) | mm | 1360×800×980 |
Turbine Center Height (from Operating Platform) | mm | 530 |
Steam Seal Type | Carbon Ring + Comb-Tooth Labyrinth Seal | |
Noise Level | dB | ≤85 |
Unit Continuous Operation Time | hr/year | 8000 |
Emergency Shut-off Device
The emergency shut-off device is a protective mechanism that prevents the rotor from exceeding the allowable rotational speed, installed on the main oil pump casing connected to the main shaft. The emergency shut-off device used in this unit is a centrifugal flyweight type, which has an eccentric weight mounted radially on the main oil pump casing. At normal rotational speeds, a spring force balances it. When the unit's speed exceeds the rated speed by 9-11%, the flyweight is thrown out, causing the emergency shut-off throttle to disengage and activate.