Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)

Product Details
Customization: Available
After-sales Service: Provide Installation and Commissioning Guidance.
Warranty: One Year
Manufacturer/Factory & Trading Company
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
  • Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
  • Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
  • Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
  • Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
  • Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Security System
  • After Sales Service
Overview

Basic Info.

Model NO.
T530
Power
300-1500kw
Generator Type
Driving Pumps
Output Type
300-1500kw
Certification
CCC, ISO
Standard
Nonstandard
Type
Back Pressure
Inlet Steam Press
2~6 MPa(a)
Inlet Steam Temperature
≤435ºC
Rated Speed
3000rpm
Weight
3.1t
Transport Package
Wooden Box
Specification
1900× 1450× 1540
Trademark
RENAO
Origin
China

Product Description

Product Description

The T530 steam turbine is a single - stage back - pressure steam turbine. It has a velocity - compounded stage impeller with an impeller pitch circle diameter of 800 millimeters. The rated speed of the main shaft is 3000 revolutions per minute, and the power range is 300 - 1500 kKW. A gearbox can be installed according to user requirements to achieve speed change. The main feature of this model is to use superheated steam as the steam source to drive rotating machinery to do work, realizing the cascade utilization of energy to achieve the purpose of energy conservation and consumption reduction.

Detailed Photos

Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
Overall dimension drawing

Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
Cross-sectional drawing
 

Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
1-Chassis 
2-Elastic Bracket 
3-Front Bearing Housing 
4-Speed Sensor 
5-Emergency Trip Device 
6-Emergency Trip Device Linkage 
7-Support Thrust Front Bearing 
8-Thermal Resistor 
9-Rotor 
10-Steam Seal 
11-Cylinder 
12-Impeller Blade 
13-Rear Bearing Housing 
14-Rear Bearing 
15-Coupling

 

Optimized design

Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)
Product Parameters
Steam Turbine Body
Item Unit Data
Product Code   T530
Rated Speed (Gearbox Reduction) r/min 3000
Number of Turbine Stages   1 regulation stage
Governor Type   PLC Regulation
Overspeed Protection Method   Two-out-of-three electrical overspeed protection + mechanical overspeed protection
Overspeed Protection Actuation Speed   Rated speed × (1.09 - 1.11)
Overspeed Protection Response Time s <0.5
Vibration Value at Rated Speed mm 0.03
Vibration Value at Critical Speed mm 0.15
Maximum Axial Displacement mm ±0.4
Weight t 3.1
Bearing Lubrication Type   Forced lubrication
Bearing Alarm Temperature ºC 85
Turbine Dimensions (Length × Width × Height) mm 1900×1450×1540
Turbine Center Height (from Operating Platform) mm 960
Steam Seal Type   Comb-Tooth Labyrinth Seal
Noise Level dB 85
Unit Continuous Operation Time hr/year 8000

Auxiliary System
Item Unit Data
Oil Station Flow rate L/min 63~125
Oil Pump Configuration   Oil pressure: Adjustable from 0.3 to 1.0 MPa
Two AC oil pumps, one DC oil pump
Seal steam heater Heat Transfer Area m2 15
Cooling Water Flow Rate t/h 35
Cooling Water Pressure MPa 0.2~0.4
Cooling Water Temperature (Normal/Maximum) ºC 27/33
 
Security System

Emergency Shut-off Device
The emergency shut-off device is a protective mechanism that prevents the rotor from exceeding the allowable rotational speed, installed on the main oil pump casing connected to the main shaft. The emergency shut-off device used in this unit is a centrifugal flyweight type, which has an eccentric weight mounted radially on the main oil pump casing. At normal rotational speeds, a spring force balances it. When the unit's speed exceeds the rated speed by 9-11%, the flyweight is thrown out, causing the emergency shut-off throttle to disengage and activate.
Back-Pressure Industrial Steam Turbine for Driving Pumps (T530)

After Sales Service
Provide guidance for equipment installation and commissioning; conduct technical training; during the warranty period, if the unit fails to operate normally or components are damaged due to quality defects, the Seller shall repair them free of charge.
Warranty Period: One year.
 

 

 