The T570 steam turbine is a single - stage back - pressure steam turbine - generator set. It is equipped with a velocity - compounded stage impeller whose pitch - circle diameter is 1040 millimeters. The speed - control system employs the internationally prevalent American Woodward 505 digital controller along with a CPC electro - hydraulic converter. It adopts multi - combination valve regulation and forced lubrication, with the main shaft rotating at 3000 revolutions per minute, and is matched with a high - voltage generator. The main characteristic of this model is that it utilizes steam with a small pressure difference as the steam source to drive the steam turbine - generator for electricity generation. Its maximum power generation capacity can reach 3000 KW. It can be used to replace the desuperheating and pressure - reducing devices in the production process, generate electricity by taking advantage of the pressure difference, reduce energy consumption, and thus bring about remarkable economic benefits.
Overall dimension drawing
Cross-sectional drawing
Optimized design
Item | Unit | Data |
Product Code | T570 | |
Rated Speed (Gearbox Reduction) | r/min | 3000 |
Number of Turbine Stages | 1 regulation stage | |
Governor Type | Woodward 505+CPC | |
Overspeed Protection Method | Two-out-of-three electrical overspeed protection + mechanical overspeed protection | |
Overspeed Protection Actuation Speed | Rated speed × (1.09 - 1.11) | |
Overspeed Protection Response Time | s | <0.5 |
Vibration Value at Rated Speed | mm | ≤0.05 |
Vibration Value at Critical Speed | mm | ≤0.10 |
Maximum Axial Displacement | mm | ±0.4 |
Weight | t | 11.7 |
Bearing Lubrication Type | Forced lubrication | |
Bearing Alarm Temperature | ºC | 85 |
Turbine Dimensions (Length × Width × Height) | mm | 2860×3050×2800 |
Turbine Center Height (from Operating Platform) | mm | 1040 |
Steam Seal Type | Comb-Tooth Labyrinth Seal | |
Noise Level | dB | ≤85 |
Unit Continuous Operation Time | hr/year | 8000 |
Item | Unit | Data | |
Oil Station | Flow rate | L/min | 350 |
Oil Pump Configuration | Oil pressure: Adjustable from 0.3 to 1.0 MPa Two AC oil pumps, one DC oil pump |
||
Seal steam heater | Heat Transfer Area | m2 | 20 |
Cooling Water Flow Rate | t/h | 50 | |
Cooling Water Pressure | MPa | 0.2~0.4 | |
Cooling Water Temperature (Normal/Maximum) | ºC | 27/33 |
Emergency Shut-off Device
The emergency shut-off device is a protective mechanism that prevents the rotor from exceeding the allowable rotational speed, installed on the main oil pump casing connected to the main shaft. The emergency shut-off device used in this unit is a centrifugal flyweight type, which has an eccentric weight mounted radially on the main oil pump casing. At normal rotational speeds, a spring force balances it. When the unit's speed exceeds the rated speed by 9-11%, the flyweight is thrown out, causing the emergency shut-off throttle to disengage and activate.